Year : 2022  |  Volume : 40  |  Issue : 2  |  Page : 159-164
 

Clinical performance of one shade universal composite resin and nanohybrid composite resin as full coronal esthetic restorations in primary maxillary incisors: A randomized controlled trial


1 Department of Pedodontics and Preventive Dentistry, Vishnu Dental College, Bhimavaram, Andhra Pradesh, India
2 Department of Public Health Dentistry, Vishnu Dental College, Bhimavaram, Andhra Pradesh, India

Date of Submission26-Mar-2022
Date of Decision28-May-2022
Date of Acceptance03-Jun-2022
Date of Web Publication15-Jul-2022

Correspondence Address:
Dr. Kakarla Sri RojaRamya
Department of Pedodontics and Preventive Dentistry, Vishnu Dental College, Bhimavaram - 534 202, Andhra Pradesh
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/jisppd.jisppd_151_22

Rights and Permissions

 

   Abstract 


Background: Strip crowns are the first treatment of choice for restoring anterior teeth affected with early childhood caries. However, shade matching of resin composites is still an issue. The broad color matching ability of a recently introduced single shade composite, Omnichroma eliminates the need for shade-matching procedure, reduces composite inventory, and minimizes chair-side time. Aim: The aim is to evaluate the color match, color stability, and retention of one shade universal composite resin, Omnichroma and nanohybrid resin composite, Tetric-N-Ceram. Settings and Design: The study design involves split-mouth randomized controlled trial. Materials and Methods: The study was conducted on 25 children aged 3–5 years with multi-surface caries lesions in primary maxillary anterior teeth. Teeth were allocated to two groups randomly: Group 1 – One shade universal composite, Omnichroma (n = 25), Group 2 – Nanohybrid composite, Tetric-N-Ceram (n = 25). After caries excavation and tooth preparation, teeth were restored with corresponding materials using strip crowns. Color match at baseline, color stability, and retention after 6- and 12-month follow-up were evaluated using the Modified United States Public Health Services criteria. Statistical Analysis: The Mann–Whitney U test and Wilcoxon signed-rank test were used to analyze the data. Results: On comparison of Omnichroma and Tetric-N-Ceram groups, no statistically significant difference was observed in the color match at baseline (P = 0.716) as well as color stability (P = 0.575 at 6 months and 0.990 at 12 months) and retention (P = 0.153 at 6 months and 0.226 at 12 months) at both 6- and 12-month intervals. On intragroup comparison, the difference in the color stability at 6 and 12-month interval was statistically significant (P = 0.001) for both the groups, indicating that the color stability of restorations was better at 6-month interval compared to 12-month interval. In both Omnichroma and Tetric-N-Ceram groups, retention of restorations was better at 6-month interval compared to 12-month interval and this difference was statistically significant (P = 0.025 and 0.014, respectively). Conclusion: The clinical performance of Omnichroma in terms of color match, color stability, and retention was comparable to nanohybrid composite, Tetric-N-Ceram.


Keywords: Crowns, deciduous teeth, early childhood caries, esthetics, resin composite, retention


How to cite this article:
Zulekha, Vinay C, Uloopi K S, RojaRamya KS, Penmatsa C, Ramesh M V. Clinical performance of one shade universal composite resin and nanohybrid composite resin as full coronal esthetic restorations in primary maxillary incisors: A randomized controlled trial. J Indian Soc Pedod Prev Dent 2022;40:159-64

How to cite this URL:
Zulekha, Vinay C, Uloopi K S, RojaRamya KS, Penmatsa C, Ramesh M V. Clinical performance of one shade universal composite resin and nanohybrid composite resin as full coronal esthetic restorations in primary maxillary incisors: A randomized controlled trial. J Indian Soc Pedod Prev Dent [serial online] 2022 [cited 2022 Aug 17];40:159-64. Available from: http://www.jisppd.com/text.asp?2022/40/2/159/351039





   Introduction Top


It is prudent to restore the early childhood caries involved teeth to preserve the integrity of primary dentition until its exfoliation and eruption of permanent teeth. Resin composite strip crowns or crown formers are the first choice of treatment for many clinicians, mainly because of the superior esthetics and the ease of repair if the crown subsequently chips or fractures.[1],[2] However, shade-matching of resin composite to the surrounding tooth structure remains a problem to be resolved.[3]

The tendency to produce more and more so-called natural shades of restorative material has led to a plethora of shade choices that complicates the shade matching procedure, requires more inventory, and increases cost and chairside time.[4] Moreover, artificial emulation of all the inherent features of the tooth is not always an easy task because the enamel and dentin have disparate thickness distributions in the dental crown, structure, composition, and especially optical properties.[5] The trend of shortening the restorative procedure time and simplifying color matching led to competition between dental manufacturers to develop a universal resin composite (single shade), which could match a wide range of classical shades.[6]

Omnichroma is a newly developed single-shade resin composite. The manufacturer claims it is the first material that used structural color as the primary color mechanism in composite dentistry and can mimic the color of the surrounding tooth, irrespective of its shade.[7] The structural color phenomenon is based on the discrimination of wavelengths by the interaction of incident light with nanostructures such as thin films, diffraction gratings, or photonic crystals.[8] It consists of uniform-sized supra-nano spherical filler particles of silicon dioxide (SiO2) and zirconium dioxide (ZrO2) with a particle size of 260 nm, which interact with the incident light and change the transmission of light along the red-to-yellow zone of the color spectrum, thereby allowing it to match the color of the patient's surrounding dentition.[9]

A recent study reported that Omnichroma with 260 nm spherical filler particles exhibited structural color and that their color adaptation to denture teeth of various shades was excellent.[10] However, its clinical success in various shades of human teeth, especially the primary teeth, remains unclear. Therefore, this study was carried out with an aim to evaluate the clinical performance of the novel one shade universal composite, Omnichroma®, in comparison with nanohybrid resin composite, Tetric-N-Ceram® as full coronal restorations in primary maxillary incisors.


   Materials and Methods Top


This double-blinded randomized controlled trial was carried out from July 2020 to July 2021. The clinical trial design was reviewed and approved by the Institutional review board and the ethical committee and the protocol was in accordance with the ethical standards laid down by the Helsinki declaration. The study was registered with the Clinical Trials Registry of India (CTRI/2020/03/024302).

The sample size was calculated from the previous study by Pereira Sanchez et al.[10] The Gpower software version 3.1.9.7 (Heinrich-Heine-Universitat Dusseldorf, Dusseldorf, Germany) for power analysis indicated that a total of 32 teeth (corresponding to achieve 80% power with 95% confidence) were required. Given the possibility of 20% attrition in subsequent follow-ups, nine teeth were added to each group, and therefore, a total of 25 teeth were included per group.

After screening the children attending the outpatient department of Pediatric and Preventive dentistry, 25 children aged 3–5 years with multi-surface carious lesions in primary maxillary incisors involving enamel or enamel and dentin only with at least two carious surfaces, and at least two-thirds of the crown persisting after caries removal and those requiring complete coronal restoration were included in the study. Children having deep carious lesions with pulpal involvement or any signs of abscess/sinus tract/root resorption, medically compromised patients, and those participating in other studies were excluded. Details of the study were shared with the patients and parents before the start of the trial, and informed consent was obtained from the participants parents.

The present study was carried out using a split-mouth design, and a total of 50 primary maxillary incisors were included. Computer-generated block randomization technique was used to randomly allocate the teeth into the two treatment groups: Group I – One shade universal composite, Omnichroma (Tokuyama, CA, USA) (test group), Group II – Conventional composite, Tetric-N-Ceram (Ivoclar Vivadent, Schaan) (control group). The outcome assessor and data analyst were kept blinded to the allocation, whereas the operator could not be blinded since the control group requires shade selection.

Shade selection was made for the control group. Appropriate-sized strip crowns were selected for both groups, and rubber dam isolation was done to avoid moisture contamination. Then, the caries was excavated with round diamond burs. Tooth preparation was done by reducing the tooth interproximally by 0.5–1.0 mm, and the incisal edge by 1.5 mm using a tapered fissure bur. The labial surface was reduced by 1 mm using tapered fissure bur, and the lingual surface was reduced by 0.5 mm using flame-shaped bur. A feather edge margin was created, and the strip crowns were adapted to the cingulum of the maxillary anterior tooth by cutting the gingival margin using scissors. Vent holes were placed on the crown's mesial and distal incisal angles to remove excess material.

The prepared tooth surfaces were etched for 15 s with 37% phosphoric acid gel and then rinsed thoroughly with water. Excess moisture on the tooth surfaces was blotted out; a layer of bonding agent was applied, and light-cured for 20 s. Then, the celluloid/strip crowns were filled with corresponding composite material and inserted onto the prepared tooth, and excess resin was removed. Then, the material was light-cured, and the strip crowns were peeled off using an explorer. Postoperative occlusion was checked and adjusted accordingly. The children were recalled at 6- and 12-month interval for follow-up evaluation. Clinical photographs of teeth 51 and 61 treated with Tetric-N-Ceram and Omnichroma are illustrated in [Figure 1] and [Figure 2].
Figure 1: Clinical photographs of teeth 51 and 61 treated with Tetric-N-Ceram and Omnichroma, respectively. (a) Preoperative photograph; (b) immediate postoperative photograph; (c) 6-month follow-up photograph; (d) 12-month follow-up photograph

Click here to view
Figure 2: Clinical photographs of teeth 51 and 61 treated with Tetric-N-Ceram and Omnichroma, respectively. (a) Preoperative photograph; (b) immediate postoperative photograph; (c) 6-month follow-up photograph; (d) 12-month follow-up photograph

Click here to view


Evaluation of the color matching with the adjacent tooth tissues at baseline, color stability, and retention at 6 and 12 months were done using the Modified United States Public Health Services criteria.[11] The restorations were evaluated by two independent examiners trained in the assessment technique at the start of the study. They were precalibrated at 90% reliability on 10 patients who were not included in the study. The kappa values for inter-examiner reliability were 0.840–1.0 for Omnichroma and 0.615–1.0 for Tetric-N-Ceram groups. The agreement between the examiners was observed to be substantial to almost perfect.

The obtained data were tabulated and subjected to statistical analysis using nonparametric tests. The Wilcoxon signed-rank test was used for intra-group comparison and Mann–Whitney U test for intergroup comparison. Values of P ≤ 0.05 and P ≤ 0.000 were considered for statistical significance and high significance, respectively.


   Results Top


Participation of children through the study is depicted in the CONSORT flow diagram [Figure 3]. All the children were available for the follow-up without any dropouts.
Figure 3: CONSORT flow diagram

Click here to view


Color match

On intergroup comparison of the color match at baseline, 84% (n = 21) of restorations in the Omnichroma group and 80% (n = 20) of restorations in the Tetric-N-Ceram group were graded Alpha, the best score that represents perfect shade and translucency match with adjacent tissues. However, the difference was not statistically significant (P = 0.716), indicating that the color match of both the restorative materials was comparable [Table 1].
Table 1: Intergroup comparison of test parameters at 6- and 12-month intervals

Click here to view


Color stability

On intragroup comparison of color stability at 6- and 12-month interval, the difference was found to be statistically significant in both Omnichroma (P = 0.001) and Tetric-N-Ceram (P = 0.001) groups, indicating that the color stability of restorations was better at 6-month interval compared to 12-month interval [Table 2].
Table 2: Intra-group comparison of test parameters at 6- and 12-month intervals

Click here to view


On intergroup comparison of color stability, no statistically significant difference was found at both 6- and 12-month intervals (P = 0.575 and 0.990, respectively), indicating that the color stability of both the restorative materials was similar [Table 1].

Retention

On intragroup comparison of retention, in the Omnichroma group, 100% of restorations at 6-month interval and 92% of restorations at 12-month interval displayed the Alpha code which represents fully intact restoration. In the Tetric-N-Ceram group, 92% of restorations at 6-month interval and 80% of restorations at 12-month interval were graded as Alpha. A statistically significant difference was observed in both Omnichroma (P = 0.025) and Tetric-N-Ceram (P = 0.014) groups, indicating that the retention of restorations was better at 6-month interval compared to 12-month interval [Table 2].

On intergroup comparison of retention, no statistically significant difference was found at both 6- and 12-month intervals (P = 0.153 and 0.226, respectively), suggesting that retention of both the restorative materials was comparable [Table 1].


   Discussion Top


The use of esthetic restoration has become an essential aspect of pediatric dentistry, and color matching is paramount for the success of resin composite restorations. Few studies have investigated the color adjustment potential of Omnichroma, and currently, there is limited evidence of its in vivo performance. Furthermore, there are no studies on its use in primary teeth. Hence, the current clinical trial was conducted to evaluate and compare the clinical performance of Omnichroma with Tetric-N-Ceram in primary teeth.

The broad color-matching ability of Omnichroma eliminates the need for a shade-matching procedure and reduces composite inventory, allowing clinicians to minimize chair time, the wastage of unused composite shades, and reduce reliance on shade-matching procedures.[4] Other potential benefits include less change in the shade over time due to reduced photochemical degradation and less color distortion since their filler particle arrangement corresponds to the wavelengths of the visible light.[10],[12],[13]

Results of the current study showed that clinically the color matching ability of single shade composite, Omnichroma was comparable to multi-shade composite, Tetric-N-Ceram in primary teeth. The uniformly sized and shaped supra-nano-filled particles might have contributed largely to the shade matching ability of this novel esthetic composite resin. Similarly, Durand et al. and Pereira Sanchez et al. concluded that Omnichroma exhibited a significant and most pronounced color adjustment potential than the frequently used resin composites such as Filtek Supreme Ultra, TPH Spectra, Herculite Ultra, and Tetric EvoCeram.[9],[10]

On the contrary, studies conducted by de Abreu et al. and AlHamdan et al. showed that multi-shade composites presented better color matching ability than the single-shade composite.[14],[15] This was attributed to the difference in optical behavior of restoration in the anterior or posterior segment of the dental arch. The dark background of the oral cavity might influence the translucency of anterior restorations, resulting in greyish restorations. The use of the blocker agent provided by the manufacturer of Omnichroma in class III restorations and restorations lacking lingual wall that compensates for the dark background of the oral cavity could be one viable answer for this problem.[16]

Color stability is the ability of materials to retain their original color. Degradation of the color of composite resins can be related to intrinsic or extrinsic factors. Internally induced discolorations are permanent and are caused by various factors, including filler type and quantity, polymer quality, insufficient polymerization as well as the photoinitiator system. Under the influence of light or heat, other components of the photoinitiator cascade, such as tertiary aromatic or aliphatic amines, tend to turn yellow or brown.[17]

In the current study, the color stability of Omnichroma was equivalent to Tetric-N-Ceram at both 6- and 12-month time intervals. Both the groups did better at 6-month time intervals. than at 12-month time interval, demonstrating that the color of the restorations deteriorated over time, though the change was clinically acceptable. This might be due to the similar amount of filler content in both materials. Omnichroma comprises uniformly shaped supra-nano spherical filler particles, which would eventually give a smoother finish to the restoration, lesser spaces between the resin-filler interface, reduces bacterial adhesion and microleakage, thereby reducing surface stains over time.

These results are in accord with an in vitro study by AlHamdan et al., who concluded that Omnichroma exhibited comparable color stability with that of a conventional composite, Filtek[15] and a study by Sensi et al., who demonstrated that Omnichroma showed the least discoloration when subjected to artificial aging.[18] Contradictory results were demonstrated by Bajabaa et al., where Omnichroma showed the highest microleakage compared to Tetric-N-Ceram. This may be explained by the presence of TEGDMA in the resin matrix of Omnichroma, which has a low-molecular-weight when compared to Bis-GMA and UDMA in Tetric-N-Ceram which considerably reduces polymerization shrinkage and microleakage.[19] Microleakage would lead to water sorption, stain penetration, and eventually discoloration.[19]

The longevity of restorations is probably the most critical factor for measuring the success of restorative therapy. Many variables affect the retention of resin composite restorations, including patient, operator, material, and tooth-related factors.[20] In the current study, Omnichroma and Tetric-N-Ceram performed similarly in terms of retention at both 6- and 12-month time intervals. However, the clinical performance of both groups was better at 6-month than at 12-month time intervals. The comparable results may be explained by the similar amount of filler content that reduces polymerization shrinkage, use of the same clinical technique, bonding agent, isolation protocol, and exposure to the same oral environment.

Clinically, Omnichroma performed similarly to Tetric-N-Ceram with excellent color match, good color stability and retention over 12 months, proving the null hypothesis. Hence, this novel single-shade resin composite can be employed as an alternative to multi-shade nanohybrid composite in pediatric patients where chair side time and child behavior are essential concerns.


   Conclusion Top


One shade universal composite resin, Omnichroma performed similarly to multi-shade nanohybrid composite, Tetric-N-Ceram in terms of the color match at baseline. The color stability and retention of Omnichroma were comparable to Tetric-N-Ceram at both 6- and 12-month intervals. In both Omnichroma and Tetric-N-Ceram, color stability and retention were reduced over time.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
   References Top

1.
Subramanyam D, Jeevanandan G. Comparison of parental satisfaction and clinical evaluation of KIDS strip crown versus 3M ESPE crown in primary anterior teeth – An in vivo study. J clin diagn. 2018;12(8):ZC9-11.  Back to cited text no. 1
    
2.
Khurana D, Indushekar KR, Saraf BG, Sheoran N, Sardana D. A randomized controlled clinical trial to evaluate and compare three chairside techniques of veneering stainless steel crowns. J Indian Soc Pedod Prev Dent 2018;36:198-205.  Back to cited text no. 2
[PUBMED]  [Full text]  
3.
Grewal N, Seth R. Comparative in vivo evaluation of restoring severely mutilated primary anterior teeth with biological post and crown preparation and reinforced composite restoration. J Indian Soc Pedod Prev Dent 2008;26:141-8.  Back to cited text no. 3
[PUBMED]  [Full text]  
4.
Clark P, Powers JM, Seybold S, Fay R, Johnson R. Primary teeth color in African-American, Caucasian, and Hispanic patients. J Dent Res. 1999;78:231.  Back to cited text no. 4
    
5.
Iyer RS, Babani VR, Yaman P, Dennison J. Color match using instrumental and visual methods for single, group, and multi-shade composite resins. J Esthet Restor Dent 2021;33:394-400.  Back to cited text no. 5
    
6.
Oivanen M, Keulemans F, Garoushi S, Vallittu PK, Lassila L. The effect of refractive index of fillers and polymer matrix on translucency and color matching of dental resin composite. Biomater Investig Dent 2021;8:48-53.  Back to cited text no. 6
    
7.
Omnichroma.com/us/resources. Dr. Peter Auster, American Dental Association, Vendor Showcase Premium Content. Available from: https://omnichroma.com/us/wp-content/uploads/sites/4/2019/03/OMNICHROMA-Product-Presentation.pdf [Last accessed on 2022 Jun 15].  Back to cited text no. 7
    
8.
Kobayashi S, Nakajima M, Furusawa K, Tichy A, Hosaka K, Tagami J. Color adjustment potential of single-shade resin composite to various-shade human teeth: Effect of structural color phenomenon. Dent Mater J 2021;40:1033-40.  Back to cited text no. 8
    
9.
Durand LB, Ruiz-López J, Perez BG, Ionescu AM, Carrillo-Pérez F, Ghinea R, et al. Color, lightness, chroma, hue, and translucency adjustment potential of resin composites using CIEDE2000 color difference formula. J Esthet Restor Dent 2021;33:836-43.  Back to cited text no. 9
    
10.
Pereira Sanchez N, Powers JM, Paravina RD. Instrumental and visual evaluation of the color adjustment potential of resin composites. J Esthet Restor Dent 2019;31:465-70.  Back to cited text no. 10
    
11.
Barnes DM, Blank LW, Gingell JC, Gilner PP. A clinical evaluation of a resin-modified. Glass ionomer restorative material. J Am Dent Assoc 1995;126:1245-53.  Back to cited text no. 11
    
12.
Shawkey MD, D'Alba L. Interactions between colour-producing mechanisms and their effects on the integumentary colour palette. Philos Trans R Soc Lond B Biol Sci 2017;372:20160536.  Back to cited text no. 12
    
13.
Fu Y, Tippets CA, Donev EU, Lopez R. Structural colors: from natural to artificial systems. Wiley Interdiscip Rev Nanomed Nanobiotechnol 2016;8:758-75.  Back to cited text no. 13
    
14.
de Abreu JL, Sampaio CS, Benalcázar Jalkh EB, Hirata R. Analysis of the color matching of universal resin composites in anterior restorations. J Esthet Restor Dent 2021;33:269-76.  Back to cited text no. 14
    
15.
AlHamdan EM, Bashiri A, Alnashmi F, Al-Saleh S, Al-Shahrani K, Al-Shahrani S, et al. Evaluation of smart chromatic technology for a single-shade dental polymer resin: An in vitro study. Appl Sci 2021;11:10108.  Back to cited text no. 15
    
16.
Hasanain FA. Flexural strength and depth of cure of single shade dental composites. J Pharm Res Int 2021;33:110-8.  Back to cited text no. 16
    
17.
Hariprasath TK, Balaji Ganesh S, Devi RG. Colour Stability of Composite Resins - A Review. Indian J Forensic Med Toxicol 2020;14:4673-8.  Back to cited text no. 17
    
18.
Sensi L, Winkler C, Geraldeli S. Accelerated aging effects on color stability of potentially color adjusting resin-based composites. Oper Dent 2021;46:188-96.  Back to cited text no. 18
    
19.
Bajabaa S, Balbaid S, Taleb M, Islam L, Elharazeen S, Alagha E. Microleakage evaluation in class V cavities restored with five different resin composites: In vitro dye leakage study. Clin Cosmet Investig Dent 2021;13:405-11.  Back to cited text no. 19
    
20.
van de Sande FH, Moraes RR, Elias RV, Montagner AF, Rodolpho PA, Demarco FF, et al. Is composite repair suitable for anterior restorations? A long-term practice-based clinical study. Clin Oral Investig 2019;23:2795-803.  Back to cited text no. 20
    


    Figures

  [Figure 1], [Figure 2], [Figure 3]
 
 
    Tables

  [Table 1], [Table 2]



 

Top
Print this article  Email this article
 

    

 
  Search
 
  
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Article in PDF (1,454 KB)
    Citation Manager
    Access Statistics
    Reader Comments
    Email Alert *
    Add to My List *
* Registration required (free)  


    Abstract
   Introduction
    Materials and Me...
   Results
   Discussion
   Conclusion
    References
    Article Figures
    Article Tables

 Article Access Statistics
    Viewed286    
    Printed18    
    Emailed0    
    PDF Downloaded61    
    Comments [Add]    

Recommend this journal


Contact us | Sitemap | Advertise | What's New | Copyright and Disclaimer | Privacy Notice
  2005 - Journal of Indian Society of Pedodontics and Preventive Dentistry | Published by Wolters Kluwer - Medknow 
Online since 1st May '05